Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.360
Filtrar
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 208-211, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605623

RESUMO

In recent years, new degradable materials have been applied to cardiovascular implants. Cardiovascular implants with different physicochemical properties and degradation properties have special endpoints for their biological evaluation. In this study, the end points of biological evaluation of degradable cardiovascular implants were reviewed by taking vascular stents and occluders as examples.


Assuntos
Implantes Absorvíveis , Sistema Cardiovascular , Stents , Materiais Biocompatíveis/química
2.
ACS Appl Mater Interfaces ; 16(14): 17267-17284, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38556996

RESUMO

Postoperative peritoneal adhesions are a prevalent clinical issue following abdominal and pelvic surgery, frequently resulting in heightened personal and societal health burdens. Traditional biomedical barriers offer limited benefits because of practical challenges for doctors and their incompatibility with laparoscopic surgery. Hydrogel materials, represented by hyaluronic acid gels, are receiving increasing attention. However, existing antiadhesive gels still have limited effectiveness or carry the risk of complications in clinical applications. Herein, we developed a novel hydrogel using polysaccharide hemoadhican (HD) as the base material and polyethylene glycol diglycidyl ether (PEGDE) as the cross-linking agent. The HD hydrogels exhibit appropriate mechanical properties, injectability, and excellent cytocompatibility. We demonstrate resistance to protein adsorption and L929 fibroblast cell adhesion to the HD hydrogel. The biodegradability and efficacy against peritoneal adhesion are further evaluated in C57BL/6 mice. Our results suggest a potential strategy for anti-postoperative tissue adhesion barrier biomaterials.


Assuntos
Implantes Absorvíveis , Hidrogéis , Ratos , Camundongos , Animais , Hidrogéis/farmacologia , Ratos Sprague-Dawley , Aderências Teciduais/prevenção & controle , Camundongos Endogâmicos C57BL , Complicações Pós-Operatórias/prevenção & controle
3.
Gen Dent ; 72(3): 70-73, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640010

RESUMO

Treatment of peri-implant diseases focuses on reducing the bacterial load and consequent infection control. The use of local antimicrobials as an adjunct to mechanical therapy may result in a better outcome. Among antimicrobials, doxycycline stands out because of its local modulation of cytokines, microbial reduction, and clinical parameters in the treatment of periodontal diseases. The objective of this case report was to describe the combined application of mechanical debridement and bioresorbable doxycycline-loaded nanospheres for the treatment of peri-implantitis in a 71-year-old man. At the 3-year evaluation, the peri-implant tissues had improved, showing decreased probing depths, an absence of bleeding on probing, and no suppuration. This case report highlights the importance of supportive therapy, which is essential for the long-term success of peri-implantitis treatment.


Assuntos
Anti-Infecciosos , Implantes Dentários , Nanosferas , Peri-Implantite , Masculino , Humanos , Idoso , Peri-Implantite/tratamento farmacológico , Peri-Implantite/microbiologia , Doxiciclina/uso terapêutico , Seguimentos , Desbridamento , Implantes Absorvíveis , Anti-Infecciosos/uso terapêutico , Resultado do Tratamento
4.
Sci Adv ; 10(16): eadj0268, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640247

RESUMO

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.


Assuntos
Implantes Absorvíveis , Transdutores , Animais , Tecnologia sem Fio , Concentração de Íons de Hidrogênio , Biomarcadores
7.
J Cardiothorac Surg ; 19(1): 130, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491553

RESUMO

GRAND FIX mesh-type plates and pins (Gunze, Kyoto, Japan) are thin, bioabsorbable fixation devices made of poly-L-lactide (PLLA) composite. These devices are new, and how best to use them in clinical practice remains to be determined. Thus, we describe our approach to rib fixation after thoracotomy in an aortic surgery using GRAND FIX mesh-type plates and pins. The advantage of our approach is that it is easy to perform, but careful attention should be paid to fix the ribs appropriately.


Assuntos
Costelas , Toracotomia , Humanos , Costelas/cirurgia , Pinos Ortopédicos , Poliésteres , Implantes Absorvíveis
8.
Medicina (Kaunas) ; 60(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38541166

RESUMO

Background and Objectives: Spring-assisted surgery is a popular option for the treatment of non-syndromic craniosynostosis. The main drawback of this procedure is the need for a second surgery for spring removal, which could be avoided if a distractor material could be metabolised over time. Iron-Manganese alloys (FeMn) have a good trade-off between degradation rate and strength; however, their biocompatibility is still debated. Materials and Methods: In this study, the neuro-compatibility of Fe-20Mn (wt.%) was assessed using standard assays. PC-12 cells were exposed to Fe-20Mn (wt.%) and stainless steel via indirect contact. To examine the cytotoxicity, a Cell Tox Green assay was carried out after 1, 2, and 3 days of incubation. Following differentiation, a neurite morphological examination after 1 and 7 days of incubation time was carried out. The degradation response in modified Hank's solution at 1, 3, and 7 days was investigated, too. Results: The cytotoxicity assay showed a higher toxicity of Fe-20Mn than stainless steel at earlier time points; however, at the latest time point, no differences were found. Neurite morphology was similar for cells exposed to Fe-20Mn and stainless steel. Conclusions: In conclusion, the Fe-20Mn alloy shows promising neuro-compatibility. Future studies will focus on in vivo studies to confirm the cellular response to Fe-20Mn.


Assuntos
Implantes Absorvíveis , Aço Inoxidável , Humanos , Teste de Materiais , Ligas
9.
Biosens Bioelectron ; 254: 116222, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38518560

RESUMO

Materials that have the ability to manipulate shapes in response to stimuli such as heat, light, humidity and magnetism offer a means for versatile, sophisticated functions in soft robotics or biomedical implants, while such a reactive transformation has certain drawbacks including high operating temperatures, inherent rigidity and biological hazard. Herein, we introduce biodegradable, self-adhesive, shape-transformable poly (L-lactide-co-ε-caprolactone) (BSS-PLCL) that can be triggered via thermal stimulation near physiological temperature (∼38 °C). Chemical inspections confirm the fundamental properties of the synthetic materials in diverse aspects, and study on mechanical and biochemical characteristics validates exceptional stretchability up to 800 % and tunable dissolution behaviors under biological conditions. The integration of the functional polymer with a bioresorbable electronic system highlights potential for a wide range of biomedical applications.


Assuntos
Técnicas Biossensoriais , Elastômeros , Elastômeros/química , Materiais Biocompatíveis/química , Implantes Absorvíveis , Polímeros/química , Poliésteres/química
10.
Sci Rep ; 14(1): 6301, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491111

RESUMO

The clinical impact of different polymer technologies in newer-generation drug-eluting stents (DESs) for patients with acute myocardial infarction (AMI) complicated by cardiogenic shock (CS) remains poorly understood. We investigated the efficacy and safety of durable polymer DESs (DP-DESs) compared with biodegradable polymer DESs (BP-DESs). A total of 620 patients who underwent percutaneous coronary intervention with newer-generation DESs for AMI complicated by CS was divided into two groups based on polymer technology: the DP-DES group (n = 374) and the BP-DES group (n = 246). The primary outcome was target vessel failure (TVF) during a 12-month follow-up, defined as a composite of cardiac death, myocardial infarction, or target vessel revascularization. Both the DP-DES and BP-DES groups exhibited low stent thrombosis rates (1.3% vs. 1.6%, p = 0.660). The risk of TVF did not significantly differ between the two groups (34.2% vs. 28.5%, hazard ratio [HR] 0.94, 95% confidence interval [CI] 0.69-1.29, p = 0.721). This finding remained consistent after adjustment with inverse probability of treatment weighting (28.1% vs. 25.1%, HR 0.98, 95% CI 0.77-1.27, p = 0.899). In AMI patients complicated by CS, the risk of a composite of cardiac death, myocardial infarction, or target vessel revascularization was not significantly different between those treated with DP-DESs and those treated with BP-DESs.Trial registration: RESCUE registry, https://clinicaltrials.gov/ct2/show/NCT02985008 , NCT02985008.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Morte , Stents Farmacológicos/efeitos adversos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Polímeros , Desenho de Prótese , Choque Cardiogênico/terapia , Choque Cardiogênico/complicações , Resultado do Tratamento
11.
Science ; 383(6687): 1096-1103, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38452063

RESUMO

Monitoring homeostasis is an essential aspect of obtaining pathophysiological insights for treating patients. Accurate, timely assessments of homeostatic dysregulation in deep tissues typically require expensive imaging techniques or invasive biopsies. We introduce a bioresorbable shape-adaptive materials structure that enables real-time monitoring of deep-tissue homeostasis using conventional ultrasound instruments. Collections of small bioresorbable metal disks distributed within thin, pH-responsive hydrogels, deployed by surgical implantation or syringe injection, allow ultrasound-based measurements of spatiotemporal changes in pH for early assessments of anastomotic leaks after gastrointestinal surgeries, and their bioresorption after a recovery period eliminates the need for surgical extraction. Demonstrations in small and large animal models illustrate capabilities in monitoring leakage from the small intestine, the stomach, and the pancreas.


Assuntos
Implantes Absorvíveis , Fístula Anastomótica , Trato Gastrointestinal , Ultrassom , Animais , Humanos , Homeostase , Estômago , Trato Gastrointestinal/cirurgia , Fístula Anastomótica/diagnóstico por imagem , Modelos Animais
12.
Science ; 383(6687): 1058-1059, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38452097

RESUMO

An implant could allow at-home monitoring of deep-tissue changes after surgery.


Assuntos
Implantes Absorvíveis , Ultrassom , Ultrassonografia , Homeostase
13.
Nat Commun ; 15(1): 2000, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448437

RESUMO

Bioresorbable neural implants based on emerging classes of biodegradable materials offer a promising solution to the challenges of secondary surgeries for removal of implanted devices required for existing neural implants. In this study, we introduce a fully bioresorbable flexible hybrid opto-electronic system for simultaneous electrophysiological recording and optogenetic stimulation. The flexible and soft device, composed of biodegradable materials, has a direct optical and electrical interface with the curved cerebral cortex surface while exhibiting excellent biocompatibility. Optimized to minimize light transmission losses and photoelectric artifact interference, the device was chronically implanted in the brain of transgenic mice and performed to photo-stimulate the somatosensory area while recording local field potentials. Thus, the presented hybrid neural implant system, comprising biodegradable materials, promises to provide monitoring and therapy modalities for versatile applications in biomedicine.


Assuntos
Implantes Absorvíveis , Depressores do Sistema Nervoso Central , Animais , Camundongos , Optogenética , Artefatos , Encéfalo , Eletrônica , Camundongos Transgênicos
14.
Int Urogynecol J ; 35(3): 713-722, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38430238

RESUMO

INTRODUCTION AND HYPOTHESIS: Fully absorbable implants may be an alternative to permanent meshes in the correction pf pelvic organ prolapse (POP) as they may reduce adverse events by promoting tissue regeneration and collagen metabolism. This study was aimed at evaluating the long-term host and biomechanical response to a fully absorbable poly-4-hydroxybutyrate (P4HB) scaffold in comparison with polypropylene (PP) mesh. METHODS: Poly-4-hydroxybutyrate scaffold (n = 16) and PP mesh (n = 16) were surgically implanted in the posterior vaginal wall of parous female Dohne Merino sheep. Vaginal explants were evaluated in terms of gross necropsy, host response (immune response, collagen deposition, tissue regeneration), biomechanics, and degradation of P4HB at 12 and 24 months post-implantation. RESULTS: Gross necropsy revealed no infection or fluid collection using P4HB or PP. At 12 months, exposures were observed with both P4HB (3 out of 8) and PP (4 out of 8), whereas at 24 months, exposures were observed only with PP (4 out of 8). The tensile stiffness of the P4HB explants was maintained over time despite complete absorption of P4HB. The collagen amount of the vaginal tissue after P4HB implantation increased over time and was significantly higher than PP at 24 months. P4HB scaffolds exhibited significantly lower myofibroblast differentiation than PP meshes at 24 months. CONCLUSIONS: The P4HB scaffold allowed for gradual load transfer to the vaginal wall and resulted in mechanically self-sufficient tissue. P4HB scaffold had a more favorable host response than PP mesh, with higher collagen content, lower myofibroblastic differentiation, and no exposures at 24 months. P4HB scaffolds have potential as an alternative to permanent implants in treating POP.


Assuntos
Prolapso de Órgão Pélvico , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Prolapso de Órgão Pélvico/metabolismo , Vagina/cirurgia , Vagina/metabolismo , Colágeno/metabolismo , Implantes Absorvíveis , Cicatrização , Telas Cirúrgicas/efeitos adversos
15.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 380-386, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500435

RESUMO

Objective: To review the research progress of magnesium and magnesium alloy implants in the repair and reconstruction of sports injury. Methods: Relevant literature of magnesium and magnesium alloys for sports injury repair and reconstruction was extensively reviewed. The characteristics of magnesium and its alloys and their applications in the repair and reconstruction of sports injuries across various anatomical sites were thoroughly discussed and summarized. Results: Magnesium and magnesium alloys have advantages in mechanical properties, biosafety, and promoting tendon-bone interface healing. Many preclinical studies on magnesium and magnesium alloy implants for repairing and reconstructing sports injuries have yielded promising results. However, successful clinical translation still requires addressing issues related to mechanical strength and degradation behavior, where alloying and surface treatments offer feasible solutions. Conclusion: The clinical translation of magnesium and magnesium alloy implants for repairing and reconstructing sports injuries holds promise. Subsequent efforts should focus on optimizing the mechanical strength and degradation behavior of magnesium and magnesium alloy implants. Conducting larger-scale biocompatibility testing and developing novel magnesium-containing implants represent new directions for future research.


Assuntos
Traumatismos em Atletas , Medicina Esportiva , Humanos , Magnésio , Ligas , Próteses e Implantes , Teste de Materiais , Implantes Absorvíveis , Corrosão
16.
Acta Biomater ; 178: 330-339, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432350

RESUMO

Cardiac pacing with temporary epicardial pacing wires (TEPW) is used to treat rhythm disturbances after cardiac surgery. Occasionally, TEPW cannot be mechanically extracted and remain in the thorax, where they may rarely cause serious complications like migration and infection. We aim to develop bioresorbable TEPW that will dissolve over time even if postoperative removal is unsuccessful. In the present study, we demonstrate a completely bioresorbable design using molybdenum (Mo) as electric conductor and the resorbable polymers poly(D, L-lactic-co-glycolic acid) (PLGA) and polycaprolactone (PCL) for electrically insulating double-coating. We compared the pacing properties of these Mo TEPW demonstrators to conventional steel TEPW in Langendorff-perfused rat hearts and observed similar functionality. In vitro, static immersion tests in simulated body fluid for up to 28 days elucidated the degradation behaviour of uncoated Mo strands and the influence of polymer coating thereon. Degradation was considerably reduced in double-coated Mo TEPW compared to the uncoated and the PLGA-coated condition. Furthermore, we confirmed good biocompatibility of Mo degradation products in the form of low cytotoxicity in cell cultures of human cardiomyocytes and cardiac fibroblasts. STATEMENT OF SIGNIFICANCE: Temporary pacing wires are routinely implanted on the heart surface to treat rhythm disturbances in the days following cardiac surgery. Subsequently, these wires are to be removed. When removal attempts are unsuccessful, wires are cut at skin level and the remainders are left inside the chest. Retained fragments may migrate within the body or become a centre of infection. These complications may be prevented using resorbable pacing wires. We manufactured completely resorbable temporary pacing wires using molybdenum as electrical conductor and assessed their function, degradation and biological compatibility. Our study represents an important step in the development of a safer approach to the treatment of rhythm disturbances after cardiac surgery.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Animais , Ratos , Molibdênio/farmacologia , Implantes Absorvíveis , Pericárdio
17.
Int J Pharm ; 654: 123973, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38458402

RESUMO

Delivering medication to the posterior segment of the eye presents a significant challenge. Intravitreal injection has emerged as the preferred method for drug delivery to this area. However, current injectable non-biodegradable implants for fluocinolone acetonide (FA) require surgical removal after prolonged drug release, potentially affecting patient compliance. This study aimed to develop an in-situ forming biodegradable implant (ISFBI) optimal formulation containing PLGA504H and PLGA756S (50:50 w/w%) with the additive NMP solvent. The goal was to achieve slow and controlled release of FA over a two-month period with lower burst release, following a single intravitreal injection. Through morphology, rheology, stability and in-vitro release evaluations, the optimal formulation demonstrated low viscosity (0.12-1.25 Pa. s) and sustained release of FA at a rate of 0.36 µg/day from the third day up to two months. Furthermore, histopathology and in-vivo studies were conducted after intravitreal injection of the optimal formulation in rabbits' eye. Pharmacokinetic analysis demonstrated mean residence time (MRT) of 20.02 ± 0.6 days, half-life (t1/2) of 18.80 ± 0.4 days, and clearance (Cl) of 0.29 ± 0.03 ml/h for FA in the vitreous humor, indicating sustained and slow absorption of FA by the targeted retinal tissue from vitrea over the two-month period and eliminating through the anterior section of the eye, as revealed by its presence in the aqueous humor. Additionally, FA exhibited no detection in the blood and no evidence of systemic side effects or damage on the retinal layer and other organs. Based on these findings, it can be concluded that in-situ forming injectable biodegradable PLGA implants can show promise as a long-acting and controlled-release system for intraocular drug delivery.


Assuntos
Fluocinolona Acetonida , Glucocorticoides , Animais , Coelhos , Humanos , Fluocinolona Acetonida/farmacocinética , Implantes Absorvíveis , Implantes de Medicamento , Sistemas de Liberação de Medicamentos/métodos
18.
ACS Biomater Sci Eng ; 10(4): 2595-2606, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38480510

RESUMO

A novel bioresorbable drug-eluting polycaprolactone (PCL) mesh scaffold was developed, utilizing a solvent-cast additive manufacturing technique, to promote therapy of muscle injury. The degradation rate and mechanical properties strength of the PCL mesh were characterized after immersion in a buffer solution for different times. The in vitro release characteristics of vancomycin, ceftazidime, and lidocaine from the prepared mesh were evaluated using a high-performance liquid chromatography (HPLC) assay. In addition, the in vivo efficacy of PCL meshes for the repair of muscle injury was investigated on a rat model with histological examinations. It was found that the additively manufactured PCL meshes degraded by 13% after submission in buffered solution for four months. All PCL meshes with different pore sizes exhibited greater strength than rat muscle and survived through 10,000 cyclic loadings. Furthermore, the meshes could offer a sustained release of antibiotics and analgesics for more than 3 days in vitro. The results of this study suggest that drug-loaded PCL mesh exhibits superior ability to pure PCL mesh in terms of effectively promoting muscle repair in rat models. The histological assay also showed adequate biocompatibility of the resorbable meshes. The additively manufactured biodegradable drug-eluting meshes may be adopted in the future in humans for the therapy of muscle injuries.


Assuntos
Implantes Absorvíveis , Telas Cirúrgicas , Ratos , Humanos , Animais , Antibacterianos/farmacologia , Antibacterianos/química , Músculos
19.
J Mech Behav Biomed Mater ; 152: 106419, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38325169

RESUMO

Simulation of bioresorbable medical devices is hindered by the limitations of current material models. Useful simulations require that both the short- and long-term response must be considered; existing models are not physically-based and provide limited insight to guide performance improvements. This study presents an integrated degradation framework which couples a physically-based degradation model, which predicts changes in both crystallinity (Xc) and molecular weight (Mn), with the results of a micromechanical model, which predicts the effective properties of the semicrystalline polymer. This degradation framework is used to simulate the deployment of a bioresorbable PLLA (Poly (L-lactide) stent into a mock vessel and the subsequent mechanical response during degradation under different diffusion boundary conditions representing neointimal growth. A workflow is established in a commercial finite element code that couples both the immediate and long-term responses. Clinically relevant lumen loss is reported and used to compare different responses and the effect of neo-intimal tissue regrowth post-implantation on degradation and on the mechanical response is assessed. In addition, the effects of possible changes in Xc, which could occur during processing and stent deployment, are explored.


Assuntos
Implantes Absorvíveis , Polímeros , Simulação por Computador , Difusão , Peso Molecular
20.
Ann Otol Rhinol Laryngol ; 133(5): 490-494, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38372259

RESUMO

OBJECTIVE: To report outcomes of a large cohort of patients who underwent endoscopic endonasal transsphenoidal surgery (EETS) for resection of a pituitary adenoma with subsequent Resorb-X plate (RXP) sellar reconstruction. METHODS: A retrospective review of 620 EETS operations performed at a single academic center between 2005 and 2020 was conducted. RESULTS: A total of 215 EETS operations of 208 patients were identified between 2012 and 2020 who underwent reconstruction with the RXP after EETS for pituitary tumor resection with a final pathologic diagnosis of pituitary adenoma. Analysis of pooled data revealed a mean preoperative tumor volume of 6.8 cm3 (range: 0.038-51.03 cm3). Postoperative cerebrospinal fluid leak occurred in 2 patients (0.93%). Postoperative meningitis occurred in 1 patient (0.47%). There were no cases of RXP extrusion. CONCLUSIONS: The rate of postoperative CSF leak and meningitis after use of the RXP for sellar reconstruction compares favorably to other methods, including use of autologous grafts and flaps. Use of RXP during EETS is a safe and efficacious method of sellar reconstruction and may obviate the need for autologous tissue reconstruction after pituitary adenoma resection.


Assuntos
Meningite , Neoplasias Hipofisárias , Humanos , Neoplasias Hipofisárias/cirurgia , Implantes Absorvíveis , Endoscopia/métodos , Retalhos Cirúrgicos , Vazamento de Líquido Cefalorraquidiano/etiologia , Vazamento de Líquido Cefalorraquidiano/cirurgia , Complicações Pós-Operatórias , Meningite/etiologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...